Blow & Go 4500 certified sensor with ENAC traceability

150,00 123,97 without vat

Electrochemical sensor replacement module pre-calibrated in NATIONAL laboratory for Vending B&G 4500 breathalyzer.

These sensors are supplied with official calibration certificate with ENAC traceability issued by the prestigious quality control firm SGS that certifies the optimal reliability of the equipment.

In a few seconds you can replace the sensor with a new one without having to perform complex calibrations and ensuring an optimal level of reliability since the calibrations are carried out in a specialized laboratory with a calibration bank.

ALC Vending Blow & Go CDP 4500 Sensor

These sensors are supplied with official calibration certificate with ENAC traceability issued by the prestigious quality control firm SGS that certifies the optimal reliability of the equipment.

With the highest quality standards

logo alcoholimetros profesionales

In stock

Description

Blow & Go 4500 certified sensor with ENAC traceability

Electrochemical sensor replacement module pre-calibrated in NATIONAL laboratory for Vending B&G 4500 breathalyzer.

These sensors are supplied with official calibration certificate with ENAC traceability issued by the prestigious quality control firm SGS that certifies the optimal reliability of the equipment.

In a few seconds you can replace the sensor with a new one without having to perform complex calibrations and ensuring an optimal level of reliability since the calibrations are carried out in a specialized laboratory with a calibration bank.

ALC Vending Blow & Go CDP 4500 Sensor

These sensors are supplied with official calibration certificate with ENAC traceability issued by the prestigious quality control firm SGS that certifies the optimal reliability of the equipment.

1. Traceability and uncertainties:

The traceability of the measurements refers to the reference standards of the laboratory, periodically calibrated in national and international laboratories, in laboratories accredited by ENAC or by any other entity of the Multilateral Agreement of the EA for the mutual recognition of certificates.

The values and uncertainties assigned correspond to the object, time and conditions under which the measures were carried out, not considering the long-term stability of the instrument.

The deviation is the indication of the instrument minus the reference value of the standard.

2. Calibration procedure: Internal procedure by SGS:

Initially, the equipment is stabilized at room temperature, and its calibration is subsequently carried out using the wet steam method.

The equipment used is calibrated with ENAC traceability.

Alcoholímetro a Monedas Blow & Go CDP 4500_22

Alcoholímetro a Monedas Blow & Go CDP 4500_22

With the highest quality standards

logo alcoholimetros profesionales

Technical Specifications:

  • Sensor type: Electrochemical sensor per fuel cell (Fuel Sensor).
  • Accuracy: <0.400 ±0.020 mg/L // 0.400 – 1.000 ±5% // 1.000 – 2.000 ±20%
  • Measurement range: 0.000~2.000mg/L(0~440mg/100mL 0.000~4.000g/L0.000~0.400%BAC?0.000~2.000‰BAC)
  • Standard deviation: 0.006 mg/L.
  • Blowing time: 3.5 sec.
  • Response time: <5 sec.

 

You may also like…